WARNING:
Disconnect and lockout electrical power before attempting any service.
Failure to do so can cause shock, burns or death. We always recommend
that you call a technician from Monticello Pump Services to do any
necessary repair or installation.
Jet Pump
|
| Problem |
Probable Cause |
Solution |
| Pump Motor Not Running |
Pump starts too often, runs too long
|
You have a water-logged tank (loss of air pressure).
Check tanks for leaks. Re-charge with air pressure to proper level.
Check air volume control. |
| |
Check to see if the valve leaks. |
Replace or repair. |
| |
The pressure switch is out of adjustment. |
Adjust to proper setting and check to assure setting remains. If not,
replace pressure switch. |
| |
There are leaks in the pipe.
|
Check above-ground piping for leaks. if none, pull pump and check
all pipe connections and connection of pipe to pump. |
|
Any or all of the above All known causes are checked but system still
won't work properly. |
Call Monticello Pump Services :-)